Wednesday, 4 November 2015

electricity - High Voltage Powerlines - clarification of energy loss


I've been having a bit of trouble understanding the High-Voltage powerlines. If I was sending power from $A \rightarrow B$, we have:


Ohm's law $V = IR$



Power lost in the form of heat $P = I^2 R$


Power delivered to $B$ is $P = VI$


But using Ohm's law on the power lost formula, we get $P = V I$ also.


Does this mean that the total amount of power $A$ loses is $P_A = 2 VI$, and the total amount of power delivered to $B$ is just $P_B = VI$? Will transferring energy always result in half of it being lost?



Answer



The difficulty is that there are three voltages involved.
The voltage at the power station end $V_S$, the total voltage drop across the cables $V_L$ and the voltage at the consumer end $V_C$.


The voltages are related as follows.


$V_S=V_L+V_C$


So you have power supplied by power station is equal to the power lost in the transmission cables plus the power used by the customer.



$V_SI = V_L I+ V_CI$


So the power loss in the cables is $V_LI = RI\cdot I = I^2R$ where $R$ is the total resistance of the transmitting cables.


The reason for transmitting the power at high voltage is that then the current through the cables $I$ is less and so the ohmic loss $I^2R$ in the cables is considerably smaller.