Wednesday, 12 November 2014

homework and exercises - How fast cool down a tank of water?



I have a tank of water (2000 liter). This is a 1m length 1m width 2m high tank, made of steel. I heat it up with my furnace to e.g. 50 ºC. I would like to know how quick cool down to 20 ºC (this is my environment temperature) without insulation and with insulation. I do not need accurate calculation, an estimated value/method (minute or hour resolution) is enough for me. The type of the insulation should be a parameter in the equation, because I need to test other materials.


Is it possible to calculate this with pure math or I need to collect some sample, or is it an impossible project?



Answer



A conservative (lowest) estimate can be obtained through lumped thermal analysis. It basically assumes that the temperature of the cooling object is uniform (no $x$, $y$ or $z$ temperature gradients) during cooling. The alternative is a mathematical nightmare where I won't take you. I'll also ignore radiative losses, which are minor at these temperatures.


Lumped thermal analysis allows to apply Newton's law of cooling, which defines the rate of cooling as a rate of heat energy ($Q$) loss:


$$\frac{dQ}{dt}=kA[T(t)-T_0]$$


$k$ is a material constant, the so called heat transfer coefficient (see below the fold), depending on the insulation (you'll find estimates on many engineering sites, depending on insulating material), $A$ the total surface area of your tank, $T_0$ the environment temperature and $T(t)$ the temperature (assumed uniform) inside the tank.


During an infinitesimal drop in temperature $dT$ of the tank:



$$dQ=-mcdT(t)$$


Where $m$ is the mass of the tank and $c$ the specific heat capacity of water.


So, dividing both sides by $dt$, we obtain:


$$\frac{dQ}{dt}=-mc\frac{dT(t)}{dt}$$


And with the equations above, we get:


$$-mc\frac{dT(t)}{dt}=kA[T(t)-T_0]$$


This differential equation separates into variables easily:


$$\frac{dT(t)}{T(t)-T_0}=-\alpha dt$$


Where:


$$\alpha=\frac{kA}{mc}$$



Integrating gives:


$$\int_{T_1}^{T_2}\frac{dT(t)}{T(t)-T_0}=-\alpha \int_0^t dt$$


Or:


$$\ln \frac{T_2-T_0}{T_1-T_0}=-\alpha t$$


Where $T_1$ is the starting temperature and $T_2$ the end temperature. Note however that when you set $T_2=T_0$ then $t=+\infty$. This is normal and a consequence of Newton's law of cooling.


So you need to set $T_2$ at a more realistic value, like 95 % of $T_0$, to get some kind of an estimate for your cooling time.




Heat transfer coefficient $k$:


In the case of an insulated tank, the heat transfer coefficient is calculated from:


$$\frac{1}{k}=\frac{1}{h_{surf}}+\frac{\delta_{ins}}{\lambda_{ins}}$$



Here $h_{surf}$ is the convective heat transfer coefficient at the surface of the insulation and $\lambda_{ins}$ the heat conductivity of the insulation. $\delta_{ins}$ is the latter's thickness.