Tuesday, 8 March 2016

quantum mechanics - Messed up units!


In the article, Environment-assisted quantum transport, $\gamma$ is a constant equal to $2\pi kT/\hbar*E_{R}/(\hbar\omega_{c})$ where $T$ is the temperature, $k$ is the Boltzmann constant. Supposedly, this constant should be in units of $\rm cm^{-1}$, but when I do calculations with different values of temperature (in K), my units end up in $\rm cm/s^2$. How can the values end up in $\rm cm^{-1}$?



Answer




Supposedly, this constant should be in units of cm^-1 but when I do calculations with different values of temperature (in K), my units end up in cm/s^2.




You did something wrong. $kT$ has units of energy. Assuming $E_R$ also has units of energy and $\omega_c$ has units of inverse time means $2\pi kT/\hbar\, E_R/(\hbar\omega_c)$ has units of inverse time -- in other words, frequency.



How can the values end up in cm-1?



Wavenumber (units of inverse length) is oftentimes used in lieu of frequency (units of inverse time) for convenience.



Edit in response to comments
The reason I said "for convenience" is multi-fold. One reason is that it is very convenient to drop those physical constants. For example, the article could have said




For the FMO complex, the reorganization energy is found to be $E_R = 35\,\text{cm}^{-1}\,\hbar c$ [29] and the cutoff $\omega_c = 150\,\text{cm}^{-1}\,c$, inferred from ...



There's no reason for being that pedantically correct. Dropping those conversion factors that involve $\hbar$, $c$, and $k$ is "convenient". The numerical value of each of those constants is one in natural units. Note that this system of natural units ($\hbar = c = k = 1$) leaves one free dimension-full quantity to be resolved. Whether one uses electron-volts or centimeters, the conversion factors between mass, length, time, and temperature, are obvious. Dropping those conversion factors is "convenient" in the sense that the paper is easier to write, and it's easier to read if you know what's going on. (Physics journal papers aren't written for lay audiences. They're written for other physicists to read.)


Another reason for my use of "convenient" is that the numbers that result are humanly convenient, at least in this case. An energy of 35 cm-1 is a much more "convenient" value than is its SI equivalent, 6.95×10-22 joules. The same goes with regard to frequency. A value of 105 cm-1 is a much more convenient value than is its SI equivalent, 3.15×1012 hertz.


As a sanity check that this is exactly what the paper is doing, consider the following in the cited paper:



For the above spectral density the rate turns out to be $γ_φ(T) = 2\pi \frac {kT}{\hbar}\frac{E_R}{\hbar \omega_c}$. This gives a rough estimate for the dephasing rate at room temperature of around 300 cm−1 ...



Room temperature in this system of units is about 205 cm−1 (or being pedantically correct, $205\,\text{cm}^{-1}\,\hbar c/k$). With this, $2\pi (205\,\text{cm}^{-1}) \frac {35}{105}$ is about 300 cm-1.


No comments:

Post a Comment

Understanding Stagnation point in pitot fluid

What is stagnation point in fluid mechanics. At the open end of the pitot tube the velocity of the fluid becomes zero.But that should result...